Parameter
Parameter manual b maXX
®
1000
Document no. 5.07004.03
95
of 208
4
P1125
The parameter are used to set the analog input reference values. The min and max fre-
quencies are based on ZP0033 (during open-loop control) as shown in the following.
ZP0033 = 50.00 Hz when ZP0310 = 9
ZP0033 = 60.00 Hz when ZP0310 = 10
Figure 44: Analog input reference values 1
ZP0033 = 50.00 Hz when ZP0310 = 9
ZP0033 = 60.00 Hz when ZP0310 = 10
Figure 45: Analog input reference values 2
P1125
Minimale AVI Spannung 0.0 to 10.0 V
EE Minimum AVI voltage 0.1 V
STOP BM_u_MinimumAVIVoltage 10:1 V