4
When extension card is installed, the number of the multi function input terminals will in-
crease according to the extension card. The maximum number of the multi-function input
terminals is 12.
Figure 35: Display status external multi function input
P1106
The multi-function input terminals are falling-edge triggered. For standard b maXX
®
1000
(without extension card), there are MI1 to MI6 and ZP1106 will display 63 (111111) for
no action.
Figure 36: Display status multi function input terminal 1
P1106
Statusanzeige Multi-Funktions-Eingänge 0 to 4095
- Display the status of multi function input termi-
nals
0
A BM_u_StatusMulitFunctionInputTerminals 1:1