Parameter description
Parameter manual b maXX
®
1000
Document no. 5.07004.03 Baumüller Nürnberg GmbH
72
of 208
4.3
P1072
This parameter specifies proportional control and associated gain (P), and is used for
speed control with PG feedback.
P1073
This parameter specifies integral control and associated gain (I), and is used for speed
control with PG feedback.
P1074
This parameter limits the amount of correction by the PI control on the output frequency
when controlling speed via PG feedback. It can limit the maximum output frequency.
Figure 20: Speed control output frequency limit
P1075
When ZP2061 is set to 14, its display will be updated regularly. This update time is set
by ZP1075. The set value is multiplied by 2 ms.
P1072
PG Verstärkung P 0.0 to 10.0
EE PG proportional gain (P) 1.0
ON BM_u_PGProportionalGainP 1:1
P1073
PG Integrierzeit I 0.00 to 100.00 s
EE PG integral time 1.00 s
ON BM_u_PGIntegralTime 100:1
P1074
PG Grenzfrequenz der Geschwindigkeitsregelung 0.00 to 100.00 Hz
EE PG speed control output frequency limit 10.00 Hz
ON BM_u_PGSpeedControlOutputFrequLimit 100:1
P1075
PG Anzeigefilter Geschwindigkeitsrückführung 0 to 9999
EE PG speed feedback signal display filter 500
ON BM_u_SpeedFeedbackSignal 1:1