EasyManua.ls Logo

Becker ACU6100 - Environmental Conditions

Becker ACU6100
64 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Becker Avionics
General Description
Technical Data
DV64440.03 Issue 09 November 2019 ACU6100 21
Environmental Conditions
The tests were done in accordance with ED-14E/DO-160E under consideration of the recorded
environmental categories and conditions:
Environmental Condition
Section
Cat.
Remarks
Temperature and Altitude
4
D1
-
Ground Survival Low Temperature
4.5.1
D1
-55 °C
Operating Low Temperature
4.5.2
D1
-40 °C
Ground Survival High Temperature
4.5.3
D1
+85 °C
Short-Time Operating High Temperature
4.5.3
D1
+70 °C
Operating High Temperature
4.5.4
D1
+70 °C
In-flight Loss of Cooling
4.5.5
X
no auxiliary cooling required
Altitude
4.6.1
D1
50 000 ft
Temperature Variation
5
B
5 °C per minute
Humidity
6
B
48 h at 65 °C at 95% RH
Operational Shocks
7.2
B
6 g in all directions
Crash Safety
7.3
B
20 g shock; 20 g acceleration
Vibration 8
S
U
M
G
Explosion Atmosphere
9
X
no test performed
Waterproofness
10
X
no test performed
Fluids Susceptibility
11
X
no test performed
Sand and Dust
12
X
no test performed
Fungus Resistance
13
X
no test performed
Salt Fog
14
X
no test performed
Magnetic Effect
15
Z
less than 0.3 m
Power Input
16
B
-
Voltage Spike
17
A
-
Audio Freq. Conducted Susceptibility
18
B
-
Induced Signal Susceptibility
19
AC
-
Radio Frequency Susceptibility
20
WR
-
Emission of Radio Frequency Energy
21
M
-
Lightning Induced Transients
Susceptibility
22 A3E3X
-
Lightning Direct Effects
23
X
no test performed
Icing
24
X
no test performed
Electrostatic Discharge (ESD)
25
A
-
Fire, Flammability
26
X
no test performed

Table of Contents

Related product manuals