17Bend-Tech Dragon A400
Maintenance & Troubleshooting
Laser
03
03
Laser
Laser Troubleshooting
Symptom Cause Corrective Action
Laser not lining up with
end of tube
Material length set wrong
in software.
Check material length on machine,
verify length is correct in software
project settings.
Chuck grip set wrong in
software.
Verify the Chuck grip setting is correct
in Dragon CAM > Tube Library >
Machine > Chuck Grip. Click the
question mark to see examples of
Chuck grip settings.
Machine not homed/
calibrated correctly.
From the Bend-Tech Dragon home
interface click Machine Control, then
click Home All Axis to home the
Dragon A400. If it is determined the
machine needs to be calibrated, the
Operator can perform a full calibration
by clicking into Machine Library, and
in the Main interface click the Wizard
icon.