Symptom Cause Corrective Action
Cope at both ends of the
tube are not the same
rotation
Material not properly
secured in the Chuck.
Ensure material is tight in Chuck. If
using spacers for the material ensure
the measurements are correct.
Settings in Nesting Project
not correct.
Check the part in Edit Flat.
Y Motor Backlash
incorrect.
Remove Trolley Cover and observe
backlash on Y Motor. If incorrect adjust
on machine. Perform a Backlash
Test in Machine Library > Mechanical
Settings.
Y Motor loose/Drive Gear
loose.
Remove Trolley Cover and perform
visual and physical check of Y Motor
and Y Motor Drive Gear.
Y Motor skipping steps.
Check Ethernet connectivity. Check
to ensure Breakout Board is seated
in Motor Drivers properly. Ensure
consistent power to machine.