26 Bend-Tech Dragon A400
Maintenance & Troubleshooting
Material Support Lift
06
Adjusting Lifter Trigger Pause
The Lifter Trigger Pause should be enabled whenever the Material Support Lifter is in use. The
Lifter Trigger Pause should be set to a parameter longer than the retraction time or the Material
Support Lifter may hit the Rail.
Material Support Lift Support Retraction Settings
Setting Material Support Lift Actuation and Retraction Adjustment
Material Support Lift Retraction is pre-set at the Bend-Tech manufacturing facility. The
retraction value is typically set to roughly two seconds. If it is determined the retraction time
needs to be adjusted the Operator will be required to open the Material Support Lift enclosure
and adjust the needle valves in the air cylinder.
1. Open the Material Support Lift enclosure.
2. Locate the Material Support Lift air cylinder.
3. There are two needle valves on the air cylinder. When facing the inside of the enclosure,
the needle valve on the left adjusts the retraction speed of the Material Support Lift. The
needle valve on the right controls the actuation speed of the Material Support Lift.
4. Adjust the needle valves as needed. Screwing the needle valve in will slow the actuation,
screwing the needle out will speed up the actuation.
Symptom Cause Corrective Action
Lifter colliding with Rail
Lifter has fallen out of
adjustment
Calibrate lifter
Lifter is out of calibration
Lifter Not Homing
Lifter has fallen out of
adjustment
Lifter pausing at wrong
time
Lifter is out of calibration
Lifter too high, Trolley
hitting Lifter as it travels
down the Rail
Can out of adjustment
Call Bend-Tech service tech
Lifter bottoming out on
top of housing
Can out of adjustment
Function Setting
Material Support Lift Retraction 2 seconds
Lifter Trigger Pause
2 seconds (can be more if needed to prevent Material
Support Lift from hitting the rail.)