31Bend-Tech Dragon A400
Maintenance & Troubleshooting
X Axis Motor
07
bearing mount nut on the top side of the Trolley. Loosen the bearing mount nut just enough to
Use a ¾ in. wrench to loosen the rear eccentric bearing mount nut on the top side of the
Trolley. Loosen the bearing mount nut just enough to allow adjustment of the bearing using the
and no side-to-side or up and down play.
The Operator will typically need to adjust each bearing multiple times in order to achieve
optimal Trolley operation.
Once the eccentric bearings are adjusted so the Trolley rides smoothly along the Rail with
no side-to-side or up and down play, tighten the eccentric bearing mount nuts, then tighten
another quarter turn.