Configuration and testingConfiguration and testing
CC612(4G)_D00325_04_M_XXEN/03.2019
29
Meter serial number (OCPP)
Serial number as reported by the eHz or Modbus
meter
Meter public key (OCPP)
Public Key of the cryptography engine of the
connected eHz meter if available
Power in Watt (OCPP)
Computed power consumption in Watt from
OCPP meter
Energy in Wh (OCPP) Computed energy consumption in Wh
Meter current (Second)
Phase current in Ampere measured by OCPP
meter
Energy Manager Main State Energy manager module‘s state and current
Temperature Monitoring State
Temperature monitoring module‘s state and
current
Peer group State Peer group module‘s state and current
Second Meter State Second meter module‘s state and current
External Input State External input module‘s state and current
Relays Temperature State Relay temperature module‘s state and current
OCPP Smart Charging State OCPP Smart Charging module‘s state and current
Operator Current Limit Current limit in Ampere set by the operator
DLM Current Applied
Available charging current assigned by DLM
Master
HLC 15118 State
High Level Communication (15118) module‘s
state and current
DLM State DLM state
Slave(s) State Slave(s) state
LED type
The type of LED device connected to the charge
controller if any
Type of Display
The type of display connected to the charge
controller if any
HMI Pattern On Relay 2 (K2)
The behaviour for the relay 2 (K2) to be used for
an external indicator light such as an LED or
blinking light. Use option "On" while vehicle
connected for integration with parking
management system by Scheidt & Bachmann. To
use two contactors in series that are to be
controlled separately, use the function "ON while
charging".
Parameter Description
Firmware version
Firmware version currently running on the
charge point
RCMB Version
Version of the RCMB module currently connected
to the charge point
Charge controller serial number Charge controller serial number
UTC time for housekeeping reboot
The UTC hour that is used for housekeeping
reboots. The charge controller reboots after 30
days to ensure uninterrupted operation. Reboots
only occur with no vehicle connected and no
customer present. Select a UTC hour in range
[0…23].
Contactor Cycles Type2
The number of times the contactor of the type 2
socket was switching on and off
Contactor Cycles Schuko
The number of times the contactor of the Schuko
socket was switching on and off
Maximum Current
The maximal current of this charge point in
Ampere
EV name (15118 protocol) Name of the vehicle currently connected
Session ID (15118 protocol)
The generated random value which describes
the current session ID.