Technical DataTechnical Data
CC612(4G)_D00325_04_M_XXEN/03.2019
42
Environment/EMC
EMC......................................................................................................................EN 61851-1,IEC 61851-21-2 FDIS:2017-09
..................................................................................................................................................EN 301 489-1, EN 301 489-52
Operating temperature ..................................................................................................................................... -30…+70 °C
Climatic conditions acc. to IEC 60721:
Stationary use (IEC 60721-3-3) ....................................................3K5 (except condensation, water and formation of ice)
Transport (IEC 60721-3-2) .................................................................................................................................................2K2
Long-term storage (IEC 60721-3-1) .................................................................................................................................1K2
Mechanical conditions acc. to IEC 60721:
Stationary use (IEC 60721-3-3) .......................................................................................................................................3M4
Transport (IEC 60721-3-2) ................................................................................................................................................2M4
Long-term storage (IEC 60721-3-1) ..............................................................................................................................1M12
Connection
Connection cable................................................................................................................................................................RJ45
Maximum cable length...................................................................................................................................................< 3 m
Connection type (terminal block C) ........................................................................push-wire terminal
Connection properties:
rigid/flexible ........................................................................................................................0.2…1.5 mm² (AWG 24…16)
flexible with ferrule without plastic sleeve ......................................................................0.25…1.5 mm² (AWG 24…16)
flexible with ferrule with plastic sleeve ..........................................................................0.25…0.75 mm² (AWG 24…20)
Stripping length............................................................................................................................................................. 10 mm
Opening force ..................................................................................................................................0.5 - 0.6 Nm (4 - 5 Ib-in)
Connection type (terminal blocks A and B) ........................................................... screw-type terminal
Connection properties:
rigid/flexible ........................................................................................................................0.2…2.5 mm² (AWG 24…12)
flexible with ferrule without plastic sleeve ......................................................................0.25…2.5 mm² (AWG 24…14)
flexible with ferrule with plastic sleeve ............................................................................0.25…1.5 mm² (AWG 24…16)
Stripping length................................................................................................................................................................7 mm
Other
Operating mode......................................................................................................................................continuous operation
Degree of protection......................................................................................................................................................... IP20
DIN rail mounting .................................................................................................................................................... IEC 60715
Weight ..............................................................................................................................................................................
160 g
*) Surge
test is carried out at Phoenix power supply STEP-PS/1AC/12DC/1.5. The 12V cable length is less than1 meter.
8.2 Standards, approvals, certifications
The charge controller has been developed in compliance with the following standards:
EN 50581: 2012
EN 61851-1: 2011
EN 301 489-1: V2.2.0 Draft
EN 301 511 V12.5.1
EN 301 908-13 V11.1.2
EN 62311: 2008
EN 61851-22: 2002
EN 301 489-52 V1.1.0 Draft
EN 301 908-1 V11.1.1
EN 301 908-2 V11.1.2
Subject to change! The specified standards take into account the edition valid until
03.2019 unless otherwise indicated.