Configuration and testingConfiguration and testing
CC612(4G)_D00325_04_M_XXEN/03.2019
36
Charging current to reduce
temperature
Charging current value in Ampere when
temperature is above temperature threshold 1.
Temperature threshold 2
Temperature threshold necessary to stop
charging.
Ambient-CPU temperature delta
Temperature delta for measurements from CPU
temperature sensor. This value should be tuned
according to the thermal characteristics of the
charging station.
CPU performance
CPU performance setting of the ChargePoint.
"Fast" configures maximum performance;
"Normal" configures reduced performance,
which is sufficient for most use cases.
ATTENTION: please change this setting only if
you know what you are doing. Changing this
setting will result in re-flashing of the bootloader.
A reboot is required. Re-flashing will occur during
reboot. Do not power off the ChargePoint. while
the system is rebooting, as you might brick your
system!
MCB Enable
This parameter allows to enable MCB detection.
It must be "Off" when there is no MCB connected
to the controller. In CC612 the opto input C8/7 is
used.
RCD Enable
This parameter allows to enable RCD detection. It
must be "Off" when there is no RCD connected to
the controller. In CC612 the opto input C6/5 is
used.
RCD Auto Reclosure
This parameter allows to enable the automatic
reclosure of the RCD. In CC612 the auxiliary relay
output C3/4 is used.
RCD auto reclosure delay RCD auto reclosure delay in seconds
RCD auto reclosure attempts RCD auto reclosure attempts
Parameter Description
6.6 Testing
Once configuration has been completed, the charge controller needs to be tested for
operability. Testing ensures that:
• A successful boot-up has taken place
• Connectivity to the backend has been established
• Meter connectivity is possible
• Plug locking and unlocking are working
• Charging is possible
Master/Slave Mode
Master controller handles the backend
connection and may start and stop transaction
for its slaves. Slave controller connects to a
Master as its backend. Some other parameters
are automatically modified when turning this on.
IMPORTANT NOTE: In case the ChargePoint is
configured as a Slave, the ChargePoint ID should
be suffixed by the Connector ID represented by
the Slave, e.g. #002 or #5 should be appended to
the ChargePoint ID. Note: Supported is a setup
with 1 Master and 1 Slave.
RFID Slave
Turn on if an individual RFID reader is installed for
the Slave controller. Note: This parameter is only
relevant for the Master configuration. The Slave
must have it always set to "Off".
USB Config update
Allows update of the charge point configuration
via USB stick
USB Firmware update
Allows update of the charge point firmware via
USB stick
Manufacturer Password
Set a new password to access the manufacturer
web interface. This password is set as root access
for the charge point.
Parameter Description