Configuration and testingConfiguration and testing
CC612(4G)_D00325_04_M_XXEN/03.2019
32
USB Additional fixed Gateway
Setting this feature assigns an additonal gateway to the
USB0 interface of the charge controller.
Free charging mode
This allows to set the OCPP behaviour in free charging
mode. Note that in case of Master/Slave scenario the
Slave will be automatically configured to the same
mode the Master uses.
Rfid Tag for Free Charging
with OCPP Full, fixed rfid
modes
RFID Tag for Free Charging with OCPP Full, fixed RFID
modes
If in doubt allow charging
This parameter determines whether a client is allowed
to charge in case its authorization cannot be processed
because the backend is offline or not reachable. If set to
"On", the client is allowed to charge even if it cannot get
authentificated from the white list nor from local cache.
Enable cache
Parameter that enables the use of the internal cache of
RFID UID. If disabled, RFIDs even if reported from the
backend with an expiry date are not added to an
internal cache.
Cache expiry mode
The maximum validity of cache entries when OCPP
expiry date has not been set. The default setting for
such cache entries is the largest allowable system time:
2038.
List of entries in cache
List of colon-separated IDs for the cache. A maximum of
80 entries are shown. To clear the cache, the list must be
empty. The listed IDs are added, while the other cache
entries are not deleted.
RFID Tag letter case
Parameter that makes the RFID tag management
configurable to upper or lower case.
Send Authorize for
RemoteStart
This parameter determines whether after receiving an
OCPP RemoteStart request the charger should still send
an OCPP Authorize message to the backend system.
Some backends require this as OCPP could be
interpreted to require this. Some backends are upset if
this is done.
Parameter Description
Send Authorize for Stop
If enabled, the charge controller will send Authorize
messages to the backend system if a different RFID card
is used for stopping a transaction. If the backend
responds with the same parent ID for that Authorize
message, the stopping is allowed. Otherwise stopping
is rejected. Should not be activated for backends that
do not use parent IDs.
Stop Transaction Mode
This allows to modify the behaviour of the charger at
the end of a transaction. "Normal" unlocks and stops the
transaction already when the vehicle side plug is
removed. "Stop after unplugging" causes a transaction
to only be fully stopped when a cable is pulled out from
the charging station. "Only by RFID/RemoteStop" only
unlocks after the user interacts with the charger and not
already when the vehicle side plug is removed.
Restart transaction after
power loss
If this parameter is enabled, the transaction that was
interrupted by a power loss is continued once the
power is back again.
Send informative
StatusNotifications
This parameter determines whether OCPP status
notifications that are meant just for informative
purposes (such as temperature report) should be sent
to the backend system or not.
Send error
StatusNotifications
This parameter determines whether OCPP status
notifications that are meant to report an error (such as
when the plug locking system is broken) should be sent
to the backend system or not.
Send USB error
StatusNotifications
This parameter determines whether USB
communication errors between Master and Slave are
reported to the backend.
Strategy for
StatusNotification state
transitions
This parameter determines on which conditions the
charge point changes into the "Occupied" state. In
"Occupied on Charging", occupied is signaled only
when authorization is there and a cable is plugged in. In
"Occupied on Authorized/Plugged", the state changes
to "Occupied already" when the charger is authorized
with nothing connected or when a cable/vehicle is
connected, but no authorization has taken place yet.
Parameter Description