Configuration and testingConfiguration and testing
CC612(4G)_D00325_04_M_XXEN/03.2019
34
Meter values aligned data
(OCPP)
Comma-separated list of types of meter values that
should be sent as clock aligned data elements in
separate meter value messages. Supported are
"Energy.Active.Import.Register", "Power.Active.Import"
and "Current.Import".
Clock aligned data interval
(OCPP)
Interval in seconds after which a new meter value is sent
to the backend system regardless of whether a charging
transaction is ongoing or not. The sending of these
values is aligned with the full hour.
Meter configuration (Second)
Energy Management: the type of second meter, used
only for input to manage the current on the grid.
Pulses per kWh (Second S0
meter)
Energy Management: Second S0 meter pulses per kWh
Fan or heater control
configuration
This parameter allows to enable the activation of an
external fan or heater according to the housing
temperature.
Temperature threshold for
Fan or Heater Control
Temperature threshold necessary to start or stop the
fan or heater.
Tilt detection
This parameter allows to enable the tilt detection
(CC612 only).
HLC 15118 configuration
High Level (15118 protocol) Powerline Communication
configuration
Power source voltage
Single phase RMS voltage of the power source feeding
the charge point in Volts. This is used for current
calculation from power values from meter.
Phases connected to the
Charge Point
This parameter describes how many and which phases
are used.
The phase rotation of the
ChargePoint in respect to the
grid connection
The phase rotation of the charge point in respect to the
grid connection.
Check for car overload
If set to "On", the current consumed by the vehicle will
be checked against the signaled current. If the overload
is above 10 %, the signaled current will be decreased by
10 %. If the overload is above 16 %, the charging will be
stopped.
Language of Display
The language of display texts on the LCD display, if
available. Only has effect if LCD is configured.
Parameter Description
UTC time for housekeeping
reboot
The UTC hour that is used for housekeeping reboots.
The charge controller reboots after 30 days to ensure
uninterrupted operation. Reboots only occur with no
vehicle connected and no customer present. Select a
UTC hour in range [0…23].
Vehicle connection timeout
Interval (from successful authorization) until incipient
charging session is automatically canceled due to
failure of EV user to (correctly) insert the charging cable
connector(s) into the appropriate connector(s).
Lock Actuator only if
authorized
If set to "On", the locking of the actuator is made only
after successful authorization. If set to "Off", the locking
is done when the cable is plugged.
Permanently locked cable
If set to "On", the locking of the actuator is made and it
stays locked permanently.
Schuko Fixed Current
The current in Ampere (A) signaled for Schuko
connector
Garo Top Board
Enable or disable the use of the Garo Top Board for MCB
and RCD inputs.
Temperature Report Delta
Temperature change for which a new temperature
measurement report is sent to the backend system.
RCMB Delta
Residual current change for which a new residual
current report is sent to the backend system as OCCP
status notification, set to "0" to disable, value is
indicated in tenth of milliamps.
Welded contactor detection Welded contactor detection (Always enabled in CC612)
Energy management from
second meter
Enabling of energy management from second meter
Current limit for energy
management from second
meter
Current limit for energy management from second
meter in Ampere (A)
Energy management from
external input
Enabling of energy management from external input
Current limit for energy
management from external
input
Single phase RMS current limit for energy management
from external input in Ampere (A). Range: From 6 A to
80 A. Set to "0" to pause charging.
Log level Level for the logging system
Parameter Description