Configuration and testingConfiguration and testing
CC612(4G)_D00325_04_M_XXEN/03.2019
39
Authorisation AFTER connecting
Initial state: The green LED lights continuously meaning the charging system is free (
only RFID110-L1).
Step 1
The vehicle is connected to the charging system.
If the RFID110-L1
module is installed, the green LED blinks slowly
to indicate that the vehicle has been identified but not yet autho-
rised.
Step 2
The user holds an RFID card close to the card reader.
If the RFID110-L1
module is installed, the yellow LED blinks and
the white LEDs are illuminated in the form of a circular light pat-
tern to indicate that authorisation is being sought.
Step 3
If authorisation is successful:
If the RFID110-L1
module is installed, the blue charging system
LED blinks slowly and the current charging status is shown.
Alter-
native
Step 3
If authorisation is not successful:
If the RFID110-L1
module is installed, all three charging system
LEDs blink briefly. The green LED then blinks to indicate that the
vehicle has been recognised but has not yet been granted authori-
sation.
The connection to the mobile phone data network and subsequently the
backend system usually lasts anywhere between 6 and 48 hours. It is nor-
mal that after this period, a connection may be terminated by the mobile
network. The charging system detects this disconnection and automati-
cally reconnects. During the reconnect, all three LEDs on the charge cont-
roller front panel flash frequently.