Technical data
70
isoRW425_D00052_03_M_XXEN / 02.2017
Transport ................................................................................................................................................ -50…+80 ºC
Storage ................................................................................................................................................... -55…+80 ºC
Climatic class acc. to IEC 60721
Stationary use (IEC 60721-3-3)................................................................................................................................ 3K7
Transport (IEC 60721-3-2)....................................................................................................................................... 2K4
Long-time storage (IEC 60721-3-1)........................................................................................................................ 1K6
Classification of mechanical conditions acc. to IEC 60721
Stationary use (IEC 60721-3-3) ...............................................................................................................................3M7
Transport (IEC 60721-3-2) ..................................................................................................................................... 2M2
Long-term storage (IEC 60721-3-1) ...................................................................................................................... 1M3
Connection
Connection type ........................................................................................screw-type terminal or push-wire terminal
Screw-type terminal:
Nominal current....................................................................................................................................................≤ 10 A
Tightening torque...............................................................................................................0.5…0.6 Nm (5…7 lb-in)
Conductor sizes..............................................................................................................................................AWG 24-12
Stripping length.......................................................................................................................................................8 mm
rigid/flexible............................................................................................................................................0.2…2.5 mm
2
flexible with ferrules with/without plastic sleeve ...............................................................................0.25…2.5 mm
2
Multi-conductor rigid ............................................................................................................................ 0.2…1.5 mm
2
Multi-conductor flexible.........................................................................................................................0.2…1.5 mm
2
Multi-conductor flexible with ferrules without plastic sleeve.............................................................0.25…1.5 mm
2
Multi-conductor flexible with TWIN ferrules with plastic sleeve........................................................0.25…1.5 mm
2
Push-wire terminal:
Nominal current....................................................................................................................................................≤ 10 A
Conductor sizes .............................................................................................................................................AWG 24-14
Stripping length................................................................................................................................................... 10 mm
Rigid.........................................................................................................................................................0.2…2.5 mm
2
flexible without ferrules .......................................................................................................................0.75…2.5 mm
2
flexible with ferrules with/without plastic sleeve ...............................................................................0.25…2.5 mm
2
Multi-conductor flexible with TWIN ferrules with plastic sleeve..........................................................0.5…1.5 mm
2
Opening force........................................................................................................................................................... 50 N
Test opening, diameter....................................................................................................................................... 2.1 mm