136
7 - PARAMETER DESCRIPTION
These ve characteristics are congured by two parameters for each state. These parameters are named
“Seq Cntl X” and Seq Count X,” where X represents the state number of the sequencer (1-9). The “Seq
Cntl X” parameter is a binary parameter that sets each of the ve characteristics listed above. “Seq Count
X” uses bits 4,5,6 and congures the threshold that the sequencer will use in determining when to advance
to the next stage by the method programmed in the control parameter. The descriptions for “Seq Count X”
is under the title “Description of Seq Count Function”. The bit patterns of the “Seq Cntl X” parameters are
shown below.
S4 Sequencer Speed Selection (Bits 0, 1, 2)
The table below gives more information on the speed selection options available in the S4 sequencer by
programming bits 0, 1 and 2 of each state’s control parameter. The options include any Preset Speed, Max
Frequency, or allowing the reference to be determined in the normal S4 control path.
S4 Seq Cntl Parameter: Bit Denition