EasyManua.ls Logo

Berthold LB 444 K-40 - User Manual

Berthold LB 444 K-40
64 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Potassium Content
Measurement
LB 444 K-40
ID No. 55884BA2
Rev. Nr.: 00

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Berthold LB 444 K-40 and is the answer not in the manual?

Summary

System Description

Installation Procedures

Connections and Evaluation Unit

Potassium Measurement Menu

Details how to access and configure parameters for potassium content measurement.

Software Functions and Configuration

Parameter Configuration

Allows configuration of product-specific settings, detector codes, and measurement modes.

Calibration Process

Explains the process of calibrating the instrument for accurate measurements.

Getting Started and Operation

Quick Installation Overview

Provides a step-by-step summary of the installation process.

Initial System Setup

Detailed steps for initial system configuration including basic settings and parameter selection.

Basic Settings Configuration

Guides through essential initial configurations like password, date, time, and language.

Calibration Procedure

Details the prerequisites and step-by-step procedure for instrument calibration.

Calibration Checking and Correction

Methods for verifying calibration and making minor result adjustments.

Error Message Handling

Lists and explains error codes, their causes, remedies, and how to acknowledge them.

Technical Data

Service Instructions

General Service Safety

General safety guidelines applicable to all service procedures.

Service Operations

Detector Plateau Check

Describes performing a plateau check to verify detector functionality.

Detector Component Service

Visual inspection and replacement procedures for crystal-multiplier assembly and photomultipliers.

Summary

System Description

Installation Procedures

Connections and Evaluation Unit

Potassium Measurement Menu

Details how to access and configure parameters for potassium content measurement.

Software Functions and Configuration

Parameter Configuration

Allows configuration of product-specific settings, detector codes, and measurement modes.

Calibration Process

Explains the process of calibrating the instrument for accurate measurements.

Getting Started and Operation

Quick Installation Overview

Provides a step-by-step summary of the installation process.

Initial System Setup

Detailed steps for initial system configuration including basic settings and parameter selection.

Basic Settings Configuration

Guides through essential initial configurations like password, date, time, and language.

Calibration Procedure

Details the prerequisites and step-by-step procedure for instrument calibration.

Calibration Checking and Correction

Methods for verifying calibration and making minor result adjustments.

Error Message Handling

Lists and explains error codes, their causes, remedies, and how to acknowledge them.

Technical Data

Service Instructions

General Service Safety

General safety guidelines applicable to all service procedures.

Service Operations

Detector Plateau Check

Describes performing a plateau check to verify detector functionality.

Detector Component Service

Visual inspection and replacement procedures for crystal-multiplier assembly and photomultipliers.

Berthold LB 444 K-40 Specifications

General IconGeneral
Sample TypeLiquid
ShieldingLead
Source ActivityUp to 10 MBq
OutputAnalog and digital signals
Power Supply100-240 VAC, 50/60 Hz

Related product manuals