MAN720_IMVS2000v2_IOM Rev. 6
55
Installation, Operation and Maintenance Manual Table of Contents
September 2019
MAN720_IMVS2000v2_IOM Rev. 6
Table of Contents
PARAMETERS OF THE “VIEW/SETUP MODE” MENU
PARAMETER NAME DESCRIPTION RANGE
DEFAULT
VALUE
R/W
(1)
AVAILABLE
ON (2) (3)
Al. OHBP En.
(Alarm OHBP Enabled)
Set as “No” it is disabled.
Set as “CFA” it is enabled and associated to the
“CFA St.”
Set as “ALR” it is enabled but not associated to
the “CFA St.”
See Sections 5.2.7, 8 and 5.2.3 for details.
CFA, ALR, No CFA R/W
Local, Serial,
Bus
Al. OLBP En.
(Alarm OLBP Enabled)
Set as “No” it is disabled.
Set as “CFA” it is enabled and associated to the
“CFA St.”
Set as “ALR” it is enabled but not associated to
the “CFA St.”
See Sections 5.2.7, 8 and 5.2.3 for details.
CFA, ALR, No CFA R/W
Local, Serial,
Bus
Al. CHBP En.
(Alarm CHBP Enabled)
Set as “No” it is disabled.
Set as “CFA” it is enabled and associated to the
“CFA St.”
Set as “ALR” it is enabled but not associated to
the “CFA St.”
See Sections 5.2.7, 8 and 5.2.3 for details.
CFA, ALR, No CFA R/W
Local, Serial,
Bus
Al. CLBP En.
(Alarm CLBP Enabled)
Set as “No” it is disabled.
Set as “CFA” it is enabled and associated to the
“CFA St.”
Set as “ALR” it is enabled but not associated to
the “CFA St.”
See Sections 5.2.7, 8 and 5.2.3 for details.
CFA, ALR, No CFA R/W
Local, Serial,
Bus
Al. PS1 En.
(Alarm PS1 Enabled)
Set as “No” it is disabled.
Set as “CFA” it is enabled and associated to the
“CFA St.”
Set as “ALR” it is enabled but not associated to
the “CFA St.”
See Sections 5.2.7, 8 and 5.2.3 for details.
CFA, ALR, No CFA R/W
Local, Serial,
Bus
Al. PS2 En.
(Alarm PS2 Enabled)
Set as “No” it is disabled.
Set as “CFA” it is enabled and associated to the
“CFA St.”
Set as “ALR” it is enabled but not associated to
the “CFA St.”
See Sections 5.2.7, 8 and 5.2.3 for details.
CFA, ALR, No CFA R/W
Local, Serial,
Bus
Al. PPS En.
(Alarm PPS Enabled)
Set as “No” it is disabled.
Set as “CFA” it is enabled and associated to the
“CFA St.”
Set as “ALR” it is enabled but not associated to
the “CFA St.”
See Sections 5.2.7, 8 and 5.2.3 for details.
CFA, ALR, No CFA R/W
Local, Serial,
Bus
Al. BUS En.
(Alarm BUS Enabled)
Set as “No” it is disabled.
Set as “CFA” it is enabled and associated to the
“CFA St.”
Set as “ALR” it is enabled but not associated to
the “CFA St.”
See Sections 5.2.7, 8 and 5.2.3 for details.
CFA, ALR. CFA R/W
Local, Serial,
Bus
Al. MNT En.
(Alarm MNT Enabled)
Set as “No” it is disabled.
Set as “CFA” it is enabled and associated to the
“CFA St.”
Set as “ALR” it is enabled but not associated to
the “CFA St.”
See Sections 5.2.7, 8 and 5.2.3 for details.
CFA, ALR, No ALR R/W
Local, Serial,
Bus
RS232 Baud For Bif Use only (Factory Password).
19200,
115200
115200 R/W Local