Issue 04/2022 Art. No. 7001-0365
Operating Manual
Translation of the original operating manual
MKF (E5)
Alternating climate chambers with program control
Model Model version
Art. No.
MKF 56 MKF056-230V 9020-0378, 9120-0378
MKF056-240V 9020-0389, 9120-0389
MKF 115 MKF115-400V 9020-0379, 9120-0379
MKF115-400V-C
9020-0357 (with voltage and frequency changer)
MKF 240
MKF240-400V
9020-0380, 9120-0380
MKF240-400V-C 9020-0358 (with voltage and frequency changer)
MKF 400
MKF400-400V
9020-0408, 9120-0408
MKF400-400V-C 9020-0446 (with voltage and frequency changer)
MKF 720
MKF720-400V
9020-0381, 9120-0381
MKF720-400V-C 9020-0359 (with voltage and frequency changer)
MKF 1020
MKF1020-400V
9020-0409, 9120-0409
MKF1020-400V-C
9020-0448 (with voltage and frequency changer)
MKFT (E5)
Alternating climate chambers with deep temperature and program control
Model Model version
Art. No.
MKFT 115 MKFT115-400V 9020-0382, 9120-0382
MKFT115-400V-C
9020-0362 (with voltage and frequency changer)
MKFT 240 MKFT240-400V 9020-0383, 9120-0383
MKFT240-400V-C
9020-0361 (with voltage and frequency changer)
MKFT 720
MKFT720-400V
9020-0384, 9120-0384
MKFT720-400V-C 9020-0360 (with voltage and frequency changer)
BINDER GmbH
Address: Post office box 102, 78502 Tuttlingen, Germany Phone: +49 7462 2005 0
Fax: +49 7462 2005 100 Internet: http://www.binder-world.com
E-mail: info@binder-world.com Service Hotline: +49 7462 2005 555
Service Fax: +49 7462 2005 93 555 Service E-Mail: customerservice@binder-world.com
Service Hotline USA: +1 866 885 9794 or +1 631 224 4340 x3
Service Hotline Asia Pacific: +852 390 705 04 or +852 390 705 03
Service Hotline Russia and CIS: +7 495 988 15 16

Table of Contents

Questions and Answers

  • B
    Becky SmithAug 21, 2025
    How to fix condensation at the samples in Binder MKF 400?
    • D
      Danielle HillAug 21, 2025
      If you notice condensation at the samples, it may be due to the heating-up phase occurring without bedew protection. To resolve this, use the bedew protection feature.
  • J
    Joanna JohnsonSep 3, 2025
    What to do if the Binder Laboratory Equipment chamber is heating permanently and the set-point is not maintained?
    • T
      Tyler WallaceSep 3, 2025
      If your Binder Laboratory Equipment chamber is heating permanently and not maintaining the set-point, it could be due to a defective semiconductor relay, in which case you should contact BINDER service. Alternatively, the controller may not be adjusted properly; try calibrating and adjusting the controller.
  • D
    Douglas BrennanSep 1, 2025
    Why should I not empty disinfectant into drains when using a Binder Climate chamber?
    • G
      Gabriel HernandezSep 1, 2025
      To prevent environmental damage when using your Binder Climate chamber, do NOT empty the disinfectant into drains.
  • R
    Riley JamesAug 31, 2025
    How to prevent eye damage when using a Binder Climate chamber?
    • A
      ann13Aug 31, 2025
      To prevent eye damage when operating your Binder Climate chamber, wear protective goggles.
  • H
    haley47Aug 29, 2025
    How to resolve humidity fluctuation in Binder MKF 400?
    • C
      Christopher MillerAug 29, 2025
      If the control accuracy of ± 2.5 % r.H. is not reached, it may be due to a defective door gasket. Replace the door gasket.
  • M
    melissa88Aug 27, 2025
    What causes icing at the sides of the inner chamber in Binder MKF 400 Laboratory Equipment?
    • C
      campbellnoahAug 27, 2025
      If there's icing at the sides of the inner chamber, it's likely because the set-point has been below the ambient temperature for too long. Defrost the chamber.
  • K
    kingtinaAug 26, 2025
    Why is there no or low dehumidification in my Binder Laboratory Equipment?
    • J
      Jaclyn WoodardAug 26, 2025
      If there is no or low dehumidification, it could be because the capillary tube is blocked. Contact BINDER service.
  • C
    Cynthia DavisAug 25, 2025
    Why am I getting a humidity alarm message when operating without humidity on my Binder Laboratory Equipment?
    • A
      audreyscottAug 25, 2025
      If you receive a humidity alarm message while operating without humidity (humidity switch OFF), it's because the humidity set-point is set to a value greater than 0% r.H. In Manual Mode, enter a humidity set-point of 0% r.H. In Program Mode, enter a humidity subprogram with a humidity set-point of 0% r.H.
  • A
    acochranAug 22, 2025
    What to do for condensation or icing at the sides of the inner chamber of Binder Laboratory Equipment?
    • P
      Phillip RobertsonAug 23, 2025
      If you observe condensation or icing at the sides of the inner chamber, it's likely because the set-point has been below the ambient temperature for an extended period, causing icing in the preheating chamber. Defrost the chamber.

Binder MKF 400 Specifications

General IconGeneral
Maximum Load per Shelf30 kg
Nominal Voltage230 V
Frequency50/60 Hz
Protection ClassIP 20
Temperature Range5 °C above ambient temperature to 300 °C
Heating-up Time to 150°C30 min
Recovery Time after Door was Opened for 30 seconds at 150°CApprox. 10 min
Number of Shelves Standard/Maximum2/
Control SystemMicroprocessor controller
DisplayDigital LCD
Power SupplyAC