MKF / MKFT (E5) 04/2022 page 146/176
25.5 MKFT (E5) technical data
Width, gross (including 18 mm / 0.7 in for 1 access
port (MKFT 115, 240), 36 mm / 1.4 in for 2 access
ports (MKFT 720), with plug)
mm / inch 1000 / 39.37
1135 / 44.69
1615 / 63.58
Height, gross (incl. castors)
Depth, gross (incl. cable and door handle)
Depth, gross (incl. cable and door handle) with op-
tional compressed air dryer
mm / inch 1085 / 42.72
1170 / 46.06
1400 / 55.12
Depth, gross (incl. cable and door handle) with volt-
age and frequency changer
mm / inch 1530 / 60.24
1615 / 63.58
1845 / 72.64
Wall clearance rear (minimum)
Wall clearance rear with optional compressed air
dryer or to set up the voltage and frequency
mm / inch 1000 / 39.37
1000 / 39.37
1000 / 39.37
Wall clearance sides (minimum)
Quantity of racks (regular)
Maximum permitted total load
Weight (empty)
with optional compressed air dryer
kg / lbs. 345 / 761 430 / 948 650 / 1433
Temperature data (without humidity)
Temperature range
Temperature uniformity (variation)
Average heating up speed acc. to IEC 60068-3-5
Average cooling down speed acc. to IEC 60068-3-5
Heating up time from -70 °C to 180 °C
Cooling down time from 180 °C to -70 °C
Max. heat compensation at 25 °C / 77°F