113
Reset Values
Here are the power supply parameter values after a *RST command or after
recalling Reset state.
Table 8: Reset values for power supply parameters
Power supply
parameters
Model
9120
Model
9121
Model
9122
Model
9123
Voltage 0 V 0V 0V 0 V
Voltage step 0.01 V 0.01 V 0.01 V 0.01 V
Voltage trigger 0 V 0 V 0 V 0 V
OVP circuit state ON ON ON ON
OVP trip level 33 V 22 V 63 V 33 V
Current 3.00 A 5.00 A 2.50 A 5.00 A
Current step 0.001 A 0.001 A 0.001 A 0.001 A
Current trigger 3.00 A 5.00 A 2.50 A 5.00 A
Display state ON ON ON ON
Output state OFF OFF OFF OFF
Trigger delay 0 s 0 s 0 s 0 s
Trigger source BUS BUS BUS BUS