EP600 Energy Storage System User Manual
78
Short-circuit Protection
Yes
Discharge Over Temperature
Protection
61℃
Discharge Over Temperature
Recovery
53℃
Discharge Under Temperature
Protection
-22℃
Discharge Under Temperature
Recovery
-18℃
Charge Over Temperature
Protection
56℃
Charge Over Temperature Recovery
47℃
Charge Under Temperature
Protection
-1℃
Charge Under Temperature
Recovery
1℃
Charge Strategy
BMS Orders
CC/CV
General
Item
Rating
Note
Noise
<25dB
No Fan
Number of Battery in Parallel
Up to 16 Batteries Supported
A combiner box* is
required for 5 or
more B500S.
Operating
Temperature
Charge
0℃-40℃
Charge
-20℃-40℃
Inverter connects to
the grid.
Discharge
-20℃-40℃
Storage Temperature
-20℃-40℃/Store for 1 month
0℃-35℃/ Store for 6 months
Working Humidity
5%-95%
Relative Humidity
Operating Altitude
2000m
Cooling
Forced Air Cooling
Protection Grade
IP65
Installation
Up to 4 Batteries Stacked on the Ground