737 Flight Crew Operations Manual
6.5
Boeing Proprietary. Copyright © Boeing. May be subject to export restrictions under EAR. See title page for details.
D6-27370-4Q8-SJA
6.5
HIGH OIL TEMP - Generator Drive
2 Choose one:
HIGH OIL
TEMP
GENERATOR DRIVE
HIGH OIL TEMPERATURE
Condition:
The generator drive oil temperature is high.
Action is irreversible.
1
Generator drive
DISCONNECT switch
(affected side) . . . . . Confirm . . . . Hold in the
DISCONNECT
position momentarily
This prevents generator drive damage.
APU is available for start:
APU . . . . . . . . . . . . . . . . . . . . . . START
When APU is running:
APU GEN switch
(affected side) . . . . . . . . . . . . . ON
■ ■ ■ ■
APU is not available:
Plan to land at the nearest suitable airport.
Only one main AC power source remains.
■ ■ ■ ■
March 18, 2016