737 Flight Crew Operations Manual
2.10
Boeing Proprietary. Copyright © Boeing. May be subject to export restrictions under EAR. See title page for details.
D6-27370-4Q8-SJA
2.10
1 Choose one:
2 CONT CABIN temperature
selector . . . . . . . . . . . . . . . . . . . . . . . . MANUAL
3 CONT CABIN temperature
selector . . . . . . . . . . . . . . Hold in COLD until the
AIR MIX VALVE indication
shows full COLD
4 Wait 1 minute.
▼
Continued on next page
▼
Cabin Temperature Hot
Condition:
Flight deck or passenger cabin temperature
is excessively hot. The temperature can
cause incapacitation.
Objective:
To r egai n t em pe rat ure control. If unable to
regain control, to descend and configure to
provide alternate ventilation.
Flight deck temperature is too high:
►►Go to step 2
Passenger cabin temperature is too high:
►►Go to step 9
March 24, 2017