737 Flight Crew Operations Manual
2.2
Boeing Proprietary. Copyright © Boeing. May be subject to export restrictions under EAR. See title page for details.
D6-27370-4Q8-SJA
2.2
7 If cabin altitude is controllable:
Continue manual operation to maintain correct
cabin altitude.
When the cabin altitude is at or below 10,000
feet:
Oxygen masks may be removed.
8 Checklist Complete Except Deferred Items
Descent Checklist
Pressurization . . . . Move outflow VALVE switch
to OPEN or CLOSE as needed
to control cabin altitude and rate
Recall . . . . . . . . . . . . . . . . . . . . . . . . . . Checked
Autobrake . . . . . . . . . . . . . . . . . . . . . . . . . . ___
Landing data . . . . . . . . . VREF ___, Minimums ___
Approach briefing . . . . . . . . . . . . . . . . Completed
Approach Checklist
Altimeters . . . . . . . . . . . . . . . . . . . . . . . . . . ___
▼
Continued on next page
▼
▼CABIN ALTITUDE WARNING or Rapid Depressurization
continued▼
Deferred Items
Note: Use momentary actuation of the outflow
valve switch to avoid large and rapid
pressurization changes.
March 24, 2017