5.7.5 Overheating protection
INFO If the cooktop overheats, the power is reduced or
the cooktop is switched off completely.
The device is fitted with overheating protection. The
overheating protection can be triggered if:
Cookware is heated up empty.
Oil or fat is heated on high power.
A hot cooking zone is switched on again after a power cut.
Whilst the overheating protection is active, one of the
following steps is taken:
The activated power setting is switched back to the
previous level.
The power setting P can no longer be switched on.
The set power level is reduced.
The cooktop switches off completely.
After a sufficient cooling period, the cooktop can be used
again in full.
5.7.6 Childproofing feature
The childproong feature prevents the device from being
switched on accidentally.
Power levels Safety shut-down after hrs:min
Level 1 Level 2 Level 3
1
12:00 08:24 06:00
2
10:00 06:24 04:00
3
09:00 05:12 02:30
4
08:00 04:12 02:00
5
06:00 03:18 01:30
6
04:00 02:12 01:00
7
04:00 02:12 01:00
8
03:00 01:48 00:45
9
02:00 01:18 00:30
ßp
00:05 00:05 00:05
Tab. 5.9 Safety shut-down for power levels
Warming level Safety shut-down after hrs:min
Level 1 Level 2 Level 3
12:00 08:00 04:00
Tab. 5.10 Safety shut-down for the warming level
Switch the cooking zone back on if you want to put the
cooking zone back into operation (see Operation chapter).
5.7.4 Residual heat display
If a cooking zone is still hot after switching off, there is
a risk of burns or fire. While
H
is displayed for a cooking
zone (residual heat display), do not touch the cooking
zone or place any heat-sensitive objects on top of it.
H
shown at 100% brightness: very high temperature
H
shown at 50 % brightness: high temperature
The display goes out after a sufficient cooling time
(temperature < 60°C).