No communication with the printer available, if the printer is enabled and the DX4010 is in a
normal condition.
Restore:
4 Restore the communication with the printer to a normal condition and reset the fault.
Supervise:
1. Report the printer missing fault to configured destination when the fault is detected.
Slow flash FAULT indicator (refer to Keypad Indicators, page 8 for a detailed description).
2. When the fault is reset, send the restored report to the configured destinations.
P The FAULT indicator is turned off, when there is no other system fault.
Printer Fault
Condition:
The printer condition is abnormal (e.g. printer no paper/printer buffer is overflow/...) if printer
is enabled and the DX4010 is in a normal condition.
Restore:
4 Restore the printer to a normal condition and reset the fault.
Supervise:
1. Report the printer error to configured destination when the fault is detected.
Slow flash FAULT indicator (refer to Keypad Indicators, page 8 for a detailed description).
2. When the fault is reset, send the restored report to the configured destinations.
P The FAULT indicator is turned off, when there is no other system fault.
– RF Receiver Failure
RF Receiver 1 Fault
Condition:
The receiver condition is abnormal (e.g. RF micro is removed/hold RF micro in reset/...) if a
wireless module is enabled.
Restore:
4 Restore the communication with the receiver to a normal condition and reset the fault.
For more information, refer to RF Devices, page 83.
Supervise:
1. Report the receiver fault to configured destination when the fault is detected.
Slow flash FAULT indicator (refer to Keypad Indicators, page 8 for a detailed description).
2. When the fault is reset, send the restored report to the configured destinations.
P The FAULT indicator is turned off, when there is no other system fault.
RF Receiver 1 Missing
Condition:
1. No communication with receiver available if a wireless module is enabled.
2. A RF zone, repeater or keyfob is configured, but the wireless module is disabled.
Restore:
4 Restore the communication with the receiver to a normal condition, enable the wireless
module and reset the fault. For more information, refer to RF Devices, page 83.
Supervise:
1. Report the receiver missing fault to configured destination when the fault is detected.
Slow flash FAULT indicator (refer to Keypad Indicators, page 8 for a detailed description).
2. When the fault is reset, send the restored report to the configured destinations.
P The FAULT indicator is turned off when there is no other system fault.
RF Receiver 1 Jammed
Condition:
A signal is disturbing the receiver if a wireless module is enabled.
148
en | Troubleshooting AMAX panel
2015.05 | 06 | F.01U.309.277 Installation Manual Bosch Sicherheitssysteme GmbH