Supervise:
1. Report the fault to configured destination on address 124 when the fault is detected.
Slow flash FAULT indicator (refer to Keypad Indicators, page 8 for a detailed description).
2. When the fault is reset, send the restored report to the configured destinations.
P The FAULT indicator is turned off when there is no other system fault.
7- Tamper
– System Tamper
Condition:
Onboard panel tamper input is open.
Restore:
4 Close the panel tamper input and reset the fault.
Supervise:
1. Report the tamper condition to configured destination on address 124 when the tamper
condition is detected.
Slow flash FAULT indicator (refer to Keypad Indicators, page 8 for a detailed description).
2. When the tamper condition is reset, send the restored report to the configured
destinations.
P The FAULT indicator is turned off when there is no other system fault.
– Keypad 1-16 Tamper
Condition:
Keypad 1 is open and the tamper contact is triggered.
Restore:
4 Close the keypad and reset the tamper condition.
Supervise:
1. Report the tamper condition to configured destination on address 124 when the tamper
condition is detected.
Slow flash FAULT indicator (refer to Keypad Indicators, page 8 for a detailed description).
2. When the tamper condition is reset, send the restored report to the configured
destinations.
P The FAULT indicator is turned off when there is no other system fault.
– Zone Expansion Module 1-6 Tamper
Condition:
A disassembly of DX2010 module 1, 2, 3, 4, 5, or 6 is detected and the occurrence of zone
extension module 1, 2, 3, 4, 5 or 6 is considered as a tamper condition.
Restore:
4 Restore the DX2010 module 1, 2, 3, 4, 5, or 6 to a normal condition and reset the fault.
For more information, refer to DX2010, page 16.
Supervise:
1. Report the tamper condition to configured destination on address 0124 when the tamper
condition is detected.
Slow flash FAULT indicator (refer to Keypad Indicators, page 8 for a detailed description).
2. When the tamper condition is reset, send the restored report to the configured
destinations.
P The FAULT indicator is turned off when there is no other system fault.
154
en | Troubleshooting AMAX panel
2015.05 | 06 | F.01U.309.277 Installation Manual Bosch Sicherheitssysteme GmbH