– Zone Tamper 1-16 DEOL
Condition:
Tamper contact is triggered (if the corresponding zone is programmed as DEOL).
Restore:
4 Restore the tamper contact and reset the tamper condition.
Supervise:
1. Report the sensor tamper to configured destination on address 124 when the sensor
tamper is detected.
Slow flash FAULT indicator (refer to Keypad Indicators, page 8 for a detailed description).
2. When the tamper condition is reset, send the restored report to the configured
destinations.
P The FAULT indicator is turned off when there is no other system fault.
– Zone type 1-16 Tamper
Condition:
Tamper contact (directly connected to the zone) is triggered (zone type = tamper).
Restore:
4 Restore the tamper contact and reset the tamper condition.
Supervise:
1. Report the tamper condition to configured destination on address 124 when the tamper
condition is detected.
Slow flash FAULT indicator (refer to Keypad Indicators, page 8 for a detailed description).
2. When the tamper condition is reset, send the restored report to the configured
destinations.
P The FAULT indicator is turned off when there is no other system fault.
– Keypad Lock out
Condition:
If the number of incorrect code entries reaches the specified limit (programmed in address
0499), the keypad locks.
Restore:
4 Wait until the keypad lockout time (3min) expires and reset the fault.
Supervise:
1. Report the keypad lock out to configured destination on address 124 when the keypad
lock out is detected.
Slow flash FAULT indicator (refer to Keypad Indicators, page 8 for a detailed description).
2. When the keypad lock out condition is reset, send the restored report to the configured
destinations.
P The FAULT indicator is turned off when there is no other system fault.
– RF Receiver Tamper
Condition:
A receiver is in tamper condition (e.g. when someone removes the device from its base or
pulls it out of the wall) if a wireless module is enabled.
Restore:
4 Restore the receiver and reset the tamper condition. For more information refer to RF
Devices, page 83.
Supervise:
1. Report receiver tamper fault to configured destination when the fault is detected.
AMAX panel
Troubleshooting | en 155