136 en | Keypad Installer menu Control Panels
2018.07 | 10 | F.01U.303.996 Installation Manual Bosch Security Systems, Inc.
Press Enter to edit the UPnP Enable configuration for the module. Use Previous or Next
to toggle between Yes and No..
4. Press Save or Enter. The keypad shows Parameter saved.
5. Escape from the menu.
20.1.6 [2] Network > [1] Ethernet > (choose the bus module or on-board) > [2]
Address Parameters menu
IPv4 Address
1. Enter the installer passcode, and then open the [1] Installer Menu.
2. Go to [1] Programming Menu > [2] Network > [1] Ethernet > (choose the bus module or
on-board) > [1] Module Parameters > [2] Address Parameters > [1] IP Address.
3. Press Edit or Enter to edit the IP address.
4. Delete the existing number, if necessary, and then enter the new number. Use /
Previous or /Next to move through the different bytes.
5. Press Save or Enter. The keypad shows Parameter saved.
6. Escape from the menu.
IPv4 Subnet Mask
1. Enter the installer passcode, and then open the [1] Installer Menu.
2. Go to [1] Programming Menu > [2] Network > [1] Ethernet > (choose the bus module or
on-board) > [1] Module Parameters > [2] Subnet Mask.
3. Press Edit or Enter to edit the subnet mask address.
4. Delete the existing number, if necessary, and then enter the new number. Use /
Previous or /Next to move to a different byte.
5. Press Save or Enter. The keypad shows Parameter saved.
6. Escape from the menu.
Default Gateway
1. Enter the installer passcode, and then open the [1] Installer Menu.
2. Go to [1] Programming Menu > [2] Network > [1] Ethernet > (choose the bus module or
on-board) > [2] Address Parameters > [3] Default Gateway.
3. Press Edit or Enter to edit the gateway.
4. Delete the existing number, if necessary, and then enter the new number. Use /
Previous or /Next to move to a different byte.
5. Press Save or Enter. The keypad shows Parameter saved.
6. Escape from the menu.
HTTP Port Number
1. Enter the installer passcode, and then open the [1] Installer Menu.
2. Go to [1] Programming Menu > [2] Network > [1] Ethernet > (choose the bus module or
on-board) > [2] Address Parameters > [4] Port Number.
3. Press Edit or Enter to edit the port number.
4. Delete the existing number, if necessary, and then enter the new number.
5. Press Save or Enter. The keypad shows Parameter saved.
6. Escape from the menu.