Control Panels Appendix | en 181
Bosch Security Systems, Inc. Installation Manual 2018.07 | 10 | F.01U.303.996
OnBrd 400 On-board Ethernet module
OnBrd 408-409 Plug-in Modules 1-2
22.2.3 Communication Trouble device numbers (zzzz)
Bus Keypad display # Reporting number Description
On Board Dest [1-4]
Onbrd IP
410, 420, 430, 440 Destinations 1 through 4 via On-board
Ethernet
On Board Dest [1-4]
Cell# [1-2]
418, 428, 438, 448 Destinations 1 through 4 via On-board
Cellular Module
On-Board PN Dest [1 – 32 ] 451 – 466 Personal notification destinations number
1 through 32
SDI2 Dest [1-4]
SDI2# 1
411, 421, 431, 441 Destinations 1 through 4 on SDI2
Network Module 1
SDI2 Dest [1-4]
SDI2# 2
412, 422, 432, 442 Destinations 1 through 4 on SDI2
Network Module 2
any RPS or Installer
Services Portal
programming tool
(available in
Europe, Middle
East, Africa, and
China)
499 Used for DNS lookup error of RPS
hostname
22.2.4 Special User IDs (uuuu, iiii)
To better identify the originator of some control panel events with no unique, Standard User
identified, special user IDs designate each special case. All user ID are defined in the table
below.
User ID type Keypad display Contact ID
reporting
Modem format User text
Service User 0 F00 0 “SERVICE USER”
Standard Users 1…999, 1000-2000 001…999, FFF 1…999, 1000-2000 {configured text}
Time Sync 5001 F01 5001 “AUTO TIME SYNC”
RPS or Installer
Services Portal
programming tool
(available in
Europe, Middle
East, Africa, and
China) User
5002 F02 5002/none “BY RPS”
Automation User 5003 F03 5003/none “BY AUTOMATION”
Keyswitch 5004 F04 5004 “BY KEYSWITCH”