Control Panels Control panel installation | en 33
Bosch Security Systems, Inc. Installation Manual 2018.07 | 10 | F.01U.303.996
Control panel voltage at Terminals 9 and 10) Terminal potentially causing ground fault
~ 0 VDC 4, 9, 12, 15, 17, 21
~ 13.65 VDC 5, 6, 7, 8, 26, 30
~ 2.51 VDC 11, 13, 14, 16, 17, 19, 20, 22
~ 2.44 to 3.2 VDC 24
~ 10.9 to 11.2 VDC 25
~ 7.2 VDC 28
~ 5.8VDC 29
~ 7.35 VDC 1, 2
5.3 Control panel to module wiring overview
You can use interconnect or terminal wiring to connect devices to the control panel.
If SDIx is configured for SDI2, use either SDI2 bus.
Using terminal wiring in parallel
Notice!
Wire size
For terminal wiring, use 18 AWG to 22 AWG (1.0 mm to 0.6 mm) wire.