11
Read operating mode Display the current status (mode) of the exhaust-gas
analyzer module.
Leakage test Perform a manual leak test.
Read measurment values Display current measured values of HC, CO, CO
2
,
O
2
, lambda CO
cor
and air pressure.
Read parameters Read out set parameters.
Write parameters Enter parameters which are important for the opera-
tion of the exhaust-gas analyzer module (country-
specific stipulations).
Identification Read out software version and checksum.
Test functions Check unit functions.
Read adjustment data Display setting data important for operation of the
exhaust-gas analyzer module (country-specific stipu-
lations).
Adjustment functions Settings for the exhaust-gas analyzer module.
Reset Restart the exhaust-gas analyzer module. (When this
option is selected, the exhaust-gas analyzer module
is disabled for approx. 15 s).
Error inquiry Read out the internal fault memory.
NO - Sensor Menu for operating the NO - Sensor.
4. Checking the AMM
exhaust-gas analyzer
module
Open the Exhaust gas menu and select
AMM.
Then choose the Test program
menu.
The
Function selection menu (main
menu) opens.
The Function selection menu contains the
following items: