8.5 Messages about printing functions
No. Message Possible cause Remedy Section
1200 Internal printer not connected Loose interconnecting Check that interconnecting
cables cables secure,
check continuity 12.1 and 12.4
Faulty controller PCB of
internal printer Replace controller PCB 10.21.3
Error in control module PCB Replace control module PCB 10.27
1201 Printer not ready No paper inserted Insert paper
1202 Other printer errors
1203 Incorrect text to be entered in
printer memory Software error Re-boot BEA, if error still
1204 Error linking data module present:
1205 Error unlinking data Re-install system software 5.23
1206 Error opening internal printer RAM error Check printer driver 5.11 and 5.12
interface Error in control module PCB Replace control module PCB 10.27
1207 Error opening external printer
interface
8.6 Messages about hardware test functions
No. Message Possible cause Remedy Section
1300 Time out – no characters received Error in control module PCB Replace control module PCB 10.27
1301 Error opening serial Software error Reboot BEA, if error still
interface present: Re-install system
software 5.23
1302 Error writing serial interface Faulty interface Perform interface test 5.1 - 5.4
1203 Error reading serial interface Error in control module PCB Replace control module PCB 10.27
1304 Send data different from receive data Error in control module PCB Replace control module PCB 10.27
1305 Error opening disk interface Software error Reboot BEA, if error still
present:
Re-install system software 5.23
Error in control module PCB Replace control module PCB 10.27
1306 Error reading disk Faulty disk Insert new disk
1307 Error making temporary No OS9-formatted disk Format disk using OS9 Service see EDIS
filename inserted disk.
1308 Error creating temporary file Error in voltage supply Check voltage supply 10.2 and 10.3
1309 Error writing on disk Loose interconnecting Check that interconnecting
1310 Error reading back cables cables secure, check continuity 12.1 and 12.4
1311 Error comparing data
Hard disk error Perform HD test 5.8
Format HD using Service disk 11.1.3
If error still present:
Replace HD 10.23
Error in control module PCB Replace control module PCB 10.27
1312 Time format error Software error Reboot BEA, if error still present:
1313 Error setting time Re-install system software 5.23