8.11.4 Reference numbers for errors in „Communication error“ group
No. Designation Remedy Chapter
6080 Control module timeout
6081 Control module reception fault
6082 OBDM reception error
6083 Invalid baud rate Run interface test 5.1 - 5.4
6084 Invalid KeyBytes received OBD printed circuit board faulty —> replace 10.30
6085 Communication terminated CPU printed circuit board faulty —> replace 10.27
6086 Wrong command to control module Control unit defective.
6087 Invalid checksum from control module
6088 Communication ended with error
6089 Invalid data frame (KWP2000)
6090 Control module busy
6091 Service not supported by control module
6100 Faulty dyn. OBD text Run interface test 5.1 - 5.4
6101 Error when allocating memory OBD printed circuit board faulty —> replace 10.30
6102 Error when opening OBD text file CPU printed circuit board faulty —> replace 10.27
6105 OBD module transmits unknown
special code
8.12 Reference numbers in combination with AWN.Modul
No. Designation Remedy Chapter
7099 No connection to
Awn@Chip module Check connecting cable for AWN printed circuit board
to CPU printed circuit board using ohmmeter 12.4
AWN printed circuit board faulty —> replace 10.31
If error persists, notify system administrator
as error may be in the software of the
order processing.