Ethernet Job Listing
9--3
1070 072 196-101 (00.06) GB
Bus Parameters
Via the B-button, the set bus parameters and an overview of the handled
data traffic are displayed.
Example:
COM-E name: Control_1
Ethernet address: 00-60-34-00-08-0B
Internet address: 142.2.26.146
Retransmission counter: 16
Retr.Timer: 200 Constant retransmission
Subnet mask: 255.255.0.0 Default gateway 0.0.0.0
AstKmd: 00000527
Rep-AstKmd: 00000050
Arp: 00000009
Icmp: 00000001
IP: 001FE135
Rep-Ip: 0000002E
OverrunCnt: 00000000
AstKmd: Number of executed client jobs
Rep-AstKmd: Number of message repeats with these client jobs
Arp: Number of received ARP request messages
Icmp: Number of received ICMP requests (Ping)
IP: Number of received client jobs
Rep-Ip: Number of message repeats with the received client jobs
OverrunCnt: Overruns in the Ethernet controller
Backplane Module Display
Via the P-button, the modules that have been recognized in the card rack are
displayed.
Example:
VFD 0: ZS400 BlkAdr: 00F0 0000 Version 0025 stat 0410
VFD 9: COM-E BlkAdr: 0024 0000 Version 0011 stat 0000
VFD 0 to 9 Module number in the SK table
Module type
BlkAdr Set block address of the module
Version High byte = hardware version / Low byte = s oftware version