– For multiple-channel live mode, the system displays the second stream to monitor by
default. You cannot modify manually. All channels try to synchronize (the
synchronization effect depends on your network environment). For single channel
live mode, the system opens the main stream by default.
– The system does not support alarm activation to open the video function in the
Alarm interface.
– The window display mode and the channel number are by default. For example, the max
window split mode is 16 for the 16-channel.
Playback mode
Figure 8.2: Web Client playback
The playback video window is shown by clicking the Playback button. Here you can:
– return to live video by clicking <Live>.
– select different display modes (1 or 4 cameo displays, full screen)
– assign cameras to cameos
– jump to a specific date and time to view playback video
– view a graphical timeline of the day for recording, input, or motion events
– see unit status and alarm conditions
All of these possibilities are described extensively in Search/Play, page 97.
If your web connection has low bandwidth:
– Only I-Frames are initially streamed to save bandwidth (in full screen, an I-Frame will be
streamed every second).
– Playback starts at half-speed by default (the speed can be changed to single speed by
pressing FWD).
– Exporting files may be slow.
Setup mode
Click <Setup> to enter the Setup menu where you can configure the settings for the unit.
8.3.1
8.3.2
DIVAR AN 3000 / DIVAR AN 5000 Web Client Software | en 117
Bosch Security Systems Operations Manual 2014.10 | 2.0 | AM18-Q0669