1.5.2 Planning the system with ICP-MAP0012 CAN splitter module
4 When using a CAN splitter module to split the external BDB into two independent areas,
chose one of the following wiring possibilities:
Wiring with a CAN splitter module and a MAP LSN gateway module
ICP-MAP0012 ICP-MAP0010
Wiring with two CAN splitter modules
ICP-MAP0012
ICP-MAP0012
Cable length
The cable length of the splitted external BDB depends on the number of added keypads and
of the cable diameter.
The maximum cable length is 500 m per BDB connector.
4 When planning the system with one or more CAN splitter modules, ensure to use an
appropriate cable length and diameter in accordance with the necessary number of
keypads.