12 en | Introduction MAP 5000
2019-09 | 25 | F.01U.168.332 Installation manual Bosch Security Systems B.V.
Relation of cable length, diameter and number of keypads
Cable
diameter
Number of keypads
1 2 3 4 5 6
0.6 mm 225 m 225 m 200 m 150 m 120 m 100 m
0.8 mm 400 m 400 m 350 m 275 m 220 m 200 m
1.0 mm 620 m 620 m 550 m 450 m 360 m 300 m
Notice!
These cable lengths apply only for keypads with hardware version 1.0.2. The cable lengths of
older keypads are half of the lengths displayed in the table above.
Notice!
These cable lengths apply for keypads that are mounted with an equal cable distance in
between each other.
See also
Splitting the external data bus with a CAN splitter module, page 44
1.6 System overview
This chapter shows an overview of the system as it is installed in the ICP-MAP0111 control
panel enclosure.
System installation in ICP-MAP0111 panel enclosure (hinged mounting plate closed)
ICP-MAP0111