MAP 5000 Appendices | en 81
Bosch Security Systems B.V. Installation manual 2019-09 | 25 | F.01U.168.332
3. The schedule can optionally be edited at the control center. Schedule > Behavior > May
Be Edited At Control Center.
Chime mode
If Chime Mode is activated on the control center in disarmed state, tripping of an intrusion
point with the option Chime Mode Capable leads to a one-off chime tone on the control
center.
4 Assign the point to the local area of the control center.
8.3 Requirements in accordance with SES
The basis for this requirement is the standard EN 50131 grade 3 (refer to Requirements in
accordance with EN 50131 grade 3, page 74). Deviations from this standard are already taken
into account in the fundamental behavior of the panel and / or described below.
8.3.1 Selecting the default setting
1. Select EN50131 grade 3 as the default property values setting (refer to Standard-
compliant programming, page 58).
2. If the panel validation in accordance with EN 50131 grade 3 fails, do not proceed with
programming the panel.
See also
Point types and point evaluation, page 59
Standard-compliant programming, page 58
8.3.2 Automatic arming / disarming
Arming without a warning signal is permitted if it is possible to ensure by technical or
organizational measures that there are no persons in the supervised area before arming.
Refer to Automatic arming / disarming, page 76.
Automatic arming at a predefined time with warning signal
1. Start the schedule wizard and define the time of arming.
2. As action, select Arm Area(s) Using Exit Delay.
3. Program the duration of the acoustic warning signal before arming in the area: Area
Manager > Area > Exit Delay > Normal Delay Time.
4. Deactivate the option Arm Only If Area Is Ready To Arm.
5. Optionally program automatic bypassing of points.
Automatic arming at a predefined time without warning signal
Start the schedule wizard and define the time of arming.
As action, select Arm Area(s) Immediately.
Optionally program automatic bypassing of points.
Automatic arming after disarming without warning signal
Enter the duration after disarming when automatic arming is about to take place in the
area. Area Manager > Area > Behavior > Automatic Arming after Disarming.
Optionally program automatic bypassing of points.
Disarming at a predefined time
Automatic disarming is not permitted for security reasons.
See also
Automatic arming / disarming, page 76
Arming with automatic bypass, page 76