MAP 5000 Initial set-up and programming | en 59
Bosch Security Systems B.V. Installation manual 2019-09 | 25 | F.01U.168.332
1. Make a connection to the panel.
2. Click on the MAP 5000 Panel node.
The software version is displayed in the Properties field under Control Panel Firmware
Version.
3. Click successively on the system modules in the Hardware Manager.
The software version is shown in the diagnostics field under Software Version.
P The version of the programming software RPS for MAP is displayed during start-up or
under RPS Start>RPS Options>Resources.
4.3.2 Software updates
All system modules are updated by means of the programming software RPS for MAP.
4 To carry out updates, follow the instructions in the file How to update … on the
manufacturer's CD.
4.3.3 Manufacturer authorization
In order to transfer new software to the system modules with RPS for MAP, a manufacturer
authorization may be needed on the panel side.
1. Authorize the manufacturer user by a user with corresponding permissions (see operating
manual, section Manufacturer authorization).
2. Open the control panel enclosure.
3. Activate Installer Mode (Installer button, page 66).
4. Log on at the Installer Control Center with the manufacturer's passcode. Use the user ID
000 and password 234567 when logging on for the first time. These are entered directly
in succession. The manufacturer's password can be changed after successful log-on. The
password 234567 is deactivated as a result.
4.4 Completing the installation
1. Stick the type label supplied in the main panel accessory pack on the control panel
enclosure at a location that is easily visible from outside.
2. Lock the enclosure door after completing all work.
Systems in accordance with VdS class C and EN 50131
1. On systems in accordance with VdS class C and EN 50131, screw the door closed on the
lock side with two sheet-metal screws (3.5 mm x 10 mm) from the accessory pack in
order to guarantee sufficient mechanical strength.
2. Fix the adhesive seal on the lock.
4.5 Point types and point evaluation
Overview of the Standard Point Types and their pre-set properties
Point Type Arming state Influences ready
to arm status
Disarmed Internal armed External armed
Intrusion No Yes Yes Yes
Intrusion 24 h Yes No
1
Yes Yes
Hold-up Yes No
1
Yes Yes
Amok Yes No
1
Yes Yes
Duress Yes No
1
Yes Yes
Tamper Yes No
1
Yes Yes