MAP 5000 Appendices | en 77
Bosch Security Systems B.V. Installation manual 2019-09 | 25 | F.01U.168.332
3. Program the duration of the acoustic warning signal before arming in the area: Area
Manager > Area > Exit Delay > Normal Delay Time.
4. The option Arm Only If Area Is Ready To Arm must be deactivated.
Automatic bypassing of points can be optionally programmed. For requirements, refer to
Arming with automatic bypass, page 76.
Automatic arming after disarming
4 Do not set the option Automatic Arming after Disarming for an area. The procedure does
not comply with the requirements of EN 50131.
Automatic disarming at a predefined time: defining the disarming time
1. Start the schedule wizard and define the time of disarming.
2. As action, select Disarm Area(s).
See also
Arming with automatic bypass, page 76
8.2.7 Alarm output via siren and communicator
Alarms, trouble events and other events must be output via siren and/or communicator.
4 For possible variants, refer to Sirens and communicator in accordance with EN50131 grade
3, page 63.
External alarm via siren
4 Activate the sirens at least for the following events (behavior items):
External intrusion alarm
External tamper alarm
4 Set the option Panel Wide Device.
Additional behavior items can be optionally added.
Remote alarm via communicator
4 Activate the communicator at least for the following events (Event Manager > Panel
Event Groups > Properties > Reportable Events):
External intrusion alarm
External tamper alarm
Hold-up alarm
Duress alarm
Summary trouble
Additional reportable events can be optionally added.
8.2.8 Connection to a management system
Refer to IP Interface, page 56.
8.2.9 Printer connection
Connecting the DR2020T printer is permitted only for service purposes.
8.2.10 Access levels
The standard distinguishes between four access levels (AE):
AE 1 Access for everyone, no authorization/code required
AE 2 Access for users, user passcode required
AE 3 Access for installers via control center or via RPS for MAP
AE 4 Access for manufacturers via RPS for MAP