EasyManua.ls Logo

Bosch MAP 5000 Series - 8.3.5 Tamper Surveillance of Main Panel; 8.4 Alarm Reporting Functionality

Bosch MAP 5000 Series
90 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MAP 5000 Appendices | en 85
Bosch Security Systems B.V. Installation manual 2019-09 | 25 | F.01U.168.332
8.3.5 Tamper surveillance of the main panel
Tamper switch with wall tamper
4 When mounting the enclosure and installing the tamper switch, take the wall tamper of
the panel into account (refer to Mounting the enclosure, page 17 and Installing and
connecting the tamper switch, page 51).
Location supervision of the panel
External alarm signaling by means of siren and/or remote alarm signaling with communicator
must be planned in accordance with Sirens and communicator in accordance with EN50131
grade 3, page 63.
1. In case of variants A, B and C with communicator(s) of classes 3 and 4, provide location
supervision for the panel as soon as one or more areas are armed.
It is possible to omit location supervision for variant D with class 5 communicator.
2. Realize the location supervision as a technical solution by the intrusion alarm system
itself. Therefore, ensure the EN-compliance of the requirements for disarming.
Or:
Realize the location supervision by security-relevant persons who guarantee that actions
that pose a risk to security are detected at all times at the time of the required location
supervision.
Design types of the communicators according to SES
The transmission paths for remote alarm signaling are divided into the following:
Demand-driven connection with 25-hourly (AÜA-B25) or 5-hourly function monitoring
(AÜA-B5)
Existing connection with 3-minute (AÜA-S180) or 20-second function monitoring (AÜA-
S20)
Types Transmission procedure
EN 50131 SES
Class 1
AÜA-B25
Demand-driven connection with 25-hourly function
monitoring and voice annunciation
Class 2 Demand-driven connection with 25-hourly function
monitoring and simple digital transmission
Class 3 Demand-driven connection with 25-hourly function
monitoring and digital transmission
Class 4 AÜA-B5 Demand-driven connection with 5-hourly function monitoring
and digital transmission
Class 5 AÜA-S180 Existing connection with 180-second function monitoring and
digital transmission
Class 6 AÜA-S20 Existing connection with 20-second function monitoring and
digital transmission
Tab.8.7: Communicator types
8.4 Alarm reporting
ICP-MAP5000-COM and ICP-MAP5000-SC have an integrated alarm reporting functionality.
It can be used for alarm transmission systems according to EN50136-2 SP4 or DP3. For DP3
compliant transmission, the alternate transmission path has to be wireless.

Table of Contents

Related product manuals