MAP 5000 Appendices | en 79
Bosch Security Systems B.V. Installation manual 2019-09 | 25 | F.01U.168.332
May receive history with RPS X
May perform diagnostics with RPS X
May perform software updates with RPS X X
Operations category permissions 1 2 3 4
May disable device X
May enable device X
May turn chime on/off X X
May change schedule X X
May edit blocking time X X
User category permissions 1 2 3 4
May add user X X
May delete user X X
May change user passcode X X
Event category permissions 1 2 3 4
May clear internal alarm X X
May clear external alarm X X
May clear tamper X
May clear trouble X X
May clear battery trouble X
May silence X
Remote service category permissions 1 2 3 4
May authorize manufacturer user X X
May authorize RPS user X X
Arm category permissions 1 2 3 4
May arm area X X
May disarm area X X
Can disarm only if in alarm X X
May bypass detectors X
May bypass detectors in area X
May unbypass detector X X
May switch internal program on/off X X
Status category permissions 1 2 3 4
May view area status X X
May view device status X X