Once all the letters or numbers have been added or changed press the Enter
button.
Press the Escape button twice to return to the first screen.
3.4 Setting the Units of Measurement
Insert the programming key, select “SYSTEMS”, and select “SYSTEM UNITS”. The
screen to the left will appear.
Use the Up or Down navigation buttons to move the cursor to the desired units and
press the Enter button.
Press the Escape button to return to the first screen.
3.5 Setting the Units of Measurement
Insert the programming key, select “SYSTEMS SETUP”, select “CONTROL MODE”
and select “CONVEYOR”. The screen to the left will appear.
Automatic
AutomaticAutomatic
Automatic
Is the wt/distance Closed Loop selection. In this mode both the Ground Speed
Sensor and the Conveyor Speed Sensor are in use.
Open Loop
Open LoopOpen Loop
Open Loop
In this mode only the ground speed sensor is in use.
Manual
ManualManual
Manual
In this mode neither the ground speed sensor nor the conveyor speed sensor is in
use.
Closed L
Closed LClosed L
Closed Loop
oopoop
oop (wt/area)
In this mode the ground speed sensor, the conveyor speed sensor and the spinner
speed sensor are all I use.
Kombi S
Kombi SKombi S
Kombi Spreader
preaderpreader
preader
Customer specific use only.
Using the Down navigation button to move the cursor in front of the mode of
operation desired and press the Enter button.
The screen will return to the previous screen, the system is now in the proper mode
of operation.