41/57
Bosch Rexroth Canada ı 03.10.2011 ı Revision 5.4
12 Blast Mode Configuration
12.1 Setting the Solid De-icer Blast “Mode of Operation”
Insert the programming key, select “SYSTEM SETUP”, select “BLAST MODE” and
select “SOLID”. The screen to the left will appear.
MAX OUTPUT
MAX OUTPUTMAX OUTPUT
MAX OUTPUT
When BLAST is activated in this mode, the conveyor speed will increase to
maximum speed and maximum material output.
STATIONARY MAX
STATIONARY MAXSTATIONARY MAX
STATIONARY MAX
Allows you to activate the BLAST function while the vehicle is stationary, the
conveyor speed will increase to maximum speed and maximum material output.
CLOSED
CLOSED CLOSED
CLOSED LOOP
LOOPLOOP
LOOP
Allows you to set the BAST function at a predetermined rate, when the BLAST
function is activated the output will be controlled at that rate.
OFF
OFFOFF
OFF
The BLAST function is turned off and cannot be activated by the operator.
12.2 Setting the “Fixed Ratio Pre-wetting” Blast “Mode of
Operation”
Insert the programming key, select “SYSTEM SETUP”, select “BLAST MODE” and
select “PREWET”. The screen to the left will appear.
In the Fixed Pre-wetting mode the pump is not capable of producing the required
flow for the BLAST mode. Turn the system to OFF if a fixed pre-wet system is being
used.
Using the navigation buttons, move the cursor to the desired option and press the
Enter button. The screen will return to the previous screen.
12.3 Setting the Blast “Auto Off” Time
Insert the programming key, select “SYSTEM SETUP” and select “BLAST MODE”.
The screen to the left will appear.
• Use the Down navigation button to move the cursor to “00 Sec – Auto Off” and
press the Enter button.
• Using the Left or Right navigation button, move the cursor under the number to
be changed.