30/57
Bosch Rexroth Canada ı 03.10.2011 ı Revision 5.4
Using the navigation buttons, move the cursor to the desired option and press the
Enter button. The screen will return to the previous screen.
Press the Escape button twice to return to the first screen
.
9.3 Adjusting the Spinner Speed
Insert the programming key, select “SENSORS AND VALVES”, select “SPINNER
SETUP” and select “VALVE SETTINGS”. The screen to the left will appear.
The lines numbered from 0010 to 0090 reflect the spinner speed for each setting of
the Spinner Speed Control knob as a percentage of the maximum spinner speed.
These setting can be adjusted if desired, for more even spread patterns.
In instances where the operator is allowed one spinner speed only, the optimum
speed can be determined and all settings can then be set to this value. In this
manner the operator can select any setting of the spinner control knob but receive
only one constant speed.
• Use the Down navigation button to move the cursor to first line and press the
Enter button.
• Using the Left or Right navigation button, move to the number to be changed.
• Using the Up or Down navigation button, change the number as required.
• Once all the numbers have been changed as desired, press the Enter button.
• Move down to the next line and repeat the process.
• Press the Escape button three times to return to the first screen.
9.4 Nulling the Spinner Solenoid
Insert the programming key, select “SENSORS AND VALVES”, select “SPINNER
SETUP” and select “VALVE SETTINGS”. The screen to the left will appear.
9.4.1
9.4.19.4.1
9.4.1
Minimum Nulling
Minimum NullingMinimum Nulling
Minimum Nulling
• Start the truck and operate the engine at 1500 RPM to ensure good hydraulic oil
flow.
• Press the Enter button and using the Navigational arrow move the cursor under
the last digit.
• Using the Up navigational arrow increase the output until the spinner starts to
turn.
• Using the Down navigational arrow, slowly decrease the output in small
increments until the spinner stops.
• Press the Enter button to return the cursor in front of the Min reading.