11 Anti-icing Mode
The 440 has the capability of operating as an Anti-icing Controller for a single boom
or a multiple boom anti-icing system.
11.1 Simulated Anti-icing Mode
In the simulated anti-icing mode the spreader is equipped with a single boom across
the back of the truck and is capable of applying salt/sand and pre-wetting the
salt/sand or applying a liquid de-icer for a single lane anti-icing application.
11.1.1
11.1.111.1.1
11.1.1
Selecting the Simulated Anti
Selecting the Simulated AntiSelecting the Simulated Anti
Selecting the Simulated Anti-
--
-icing Mode
icing Modeicing Mode
icing Mode
Insert the programming key, select “SYSTEM SETUP” and select SIMSPD+ANTI-ICE”,
the screen to the left will appear.
Using the navigation buttons, move the cursor to “SIM ANTI-ICING” and press the
Enter button. The screen will return to the previous screen.
Press the Escape button to return to the first screen.
11.1.2
11.1.211.1.2
11.1.2
Setting the System for Simulated Anti
Setting the System for Simulated AntiSetting the System for Simulated Anti
Setting the System for Simulated Anti-
--
-icing
icingicing
icing
Using the navigation buttons, move the cursor to “MATERIAL SETUP”, select
“PREWET 1” and press the Enter button. The screen to the left will appear.
11.1.3
11.1.311.1.3
11.1.3
Change LIQUID
Change LIQUIDChange LIQUID
Change LIQUID1 to Read PREWET
1 to Read PREWET1 to Read PREWET
1 to Read PREWET
Press Enter and using the Left or Right navigation button, move to letter to be
changed.
Using the Up or Down navigation button, change the letter as required.
Once all the letters have been changed, press the Enter button.
11.1.4
11.1.411.1.4
11.1.4
Entering the Pre
Entering the PreEntering the Pre
Entering the Pre-
--
-wetting Liquid Rates
wetting Liquid Rateswetting Liquid Rates
wetting Liquid Rates
Move the cursor to the first line of rates and press Enter.
Using the Left or Right navigation button, move to number to be changed.
Using the Up or Down navigation button, change the number as required.
Once all the numbers have been changed, press the Enter button.
Calibrate this liquid as per calibration procedure under “PREWETTING AUTO
CALIBRATION”.