Use the Down navigation button to move the cursor to the desired error function
and press the Enter button. The screen to the left will appear.
Use the Down navigation button to move the cursor to “ACTION” and press the
Enter button. The screen to the left will appear.
Error Message
Error MessageError Message
Error Message
Description
DescriptionDescription
Description
DISABLED
The error has been disa
bled from the system and is not f
unctioning
.
TAKE NO ACTION
The error message is
a warning or reminder only and
requires no action
to be taken.
GO TO OPEN
LOOP
The system will continue to function
in the Open Loop
Mode, the
application rates are now a percentage of the maximum conveyor speed
but the system still responds to ground speed input.
GO TO MANUAL
The system will continue to function in the Manual Mode, the
application rates are now a percentage of the maximum conveyor
speed, neither ground speed nor conveyor speed input are available.
OUTPUT
FROZEN
All outputs to the valves are frozen and the system will be operating.
Outputs return to normal control once the operator acknowledges the
alarm.
OUTPUT TO ZERO
All outputs go to zero when the error is activated and will remain at
zero once the operator acknowledges the alarm. The application rate
button will no longer function.
LIQUID TO ZERO
As above for the liquid only
.
LIQUID TO
MANUAL
The liquid system will continue to function in the Manual Mode, the
application rates are now a percentage of the maximum pump speed,
neither ground speed nor flow meter input is available.
Using the navigation buttons, move the cursor to the desired option and press the
Enter button. The screen will return to the previous screen. Repeat the same for
each error function.
Once all the error functions have been configured, press the Escape button once,
select “INPUTS AND OUTPUTS” and press Enter. Configure all of the “Inputs and
outputs” errors; press the Escape button twice to return to the first screen.