Bosch Rexroth IndraMotion MLC - 9.7 CDI interfaces XVID and XSER

Bosch Rexroth IndraMotion MLC
94 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
The BIOS is configured and thus ensures that all connected output
devices can be controlled while booting.
If IndraControl VPB 40.4 is supposed to simultaneously output the
screen on a connected monitor at the display port and at the VDP
operator display under Windows, this can be set in the properties of
the graphic card:
Click on the icon of the graphics driver in the taskbar and right-
click to select "Graphic properties" from the context menu. Go to
"Multiple displays" under "Display", select "Clone displays" and
press Apply.
Fig. 9-3: Graphics driver icon in the task bar
If the screen output is only set for one display device (setting "Single
display") in the properties of the graphic card, use the shortcut
<Ctrl>+<Alt>+<F1> under Windows to open a dialog to toggle the
screen output between the monitor at the display port and the VDP
operator display.
The previously described setting options are only available if a
monitor is connected to the display port.
The graphics driver stores the last output device. After a restart, the
images are only output on the last saved output device.
9.7
CDI interfaces XVID and XSER
The CDI interface is assigned to the two RJ45 sockets XSER and XVID. Connect
the operator display to these sockets. The corresponding cables are available as
accessories, see chapter 5.4 "Connecting cables for the CDI interface" on page
6.
The CDI interface includes the data interface (XSER) as well as the image
interface (XVID).
The USB signals and the digital data (touch, M-keys, LEDs and control signals)
are transferred via the data interface.
The DVI signals are transferred via the display interface.
To avoid malfunctions, use only cables listed in
chapter 5.4
"Connecting cables for the CDI interface" on page 6.
The CDI interfaces are color-coded on the device: